We offer Fire Alarm Panel for BTS Shelters. We have different versions to suit every need:
 |
Panel with Fire, Smoke, Temperature and ntrusion detection (One detector) |
 |
Panel with Smoke, Temperature and Intrusion detection (Two detector) |
 |
Panel with Fire/Smoke and Intrusion detection (No temperature) |
For the above three models we can offer following variations:
 |
LCD display |
 |
Access thru digital keypad |
 |
Programmable Time delay for Entry/Exit/Hooter |
 |
External Hooter or Internal Hooter |
 |
Manual call point (MCP) |
 |
External Reset for resetting alarms from outside the shelter |
Features of our basic model are given below, for other models pls write to us on sales@spaceage-security.com
Comprehensive Solution for Shelters For Intrusion / Smoke/Fire
Basic model
For cellular operators, specially having unmanned install ations, we feel the following needs to be monitored to ensure safety of the equipment and more importantly to ensure uptime of the equipment. The central monitoring station must know
These conditions, if unchecked can compromise the security of lacs worth of equipment in the shelter and more importantly will lead to break in service and hence dis-satisfied customers.
Keeping the above in mind, we have developed a comprehensive solution that incorporates all the features in a single box, that operates on 48V DC/ 24V DC. (We have a common panel for 24V DC and 48V DC, without any change in settings )
Our Basic Fire Panel has following features:
 |
Central control panel |
| |
- One Intrusion zone
- One Temperature Zone
- One Fire Zone
|
 |
Whenever a zone is activated through it’s sensor, the following outputs are there |
| |
-
Corresponding zone LED lights up on Central Panel
-
In-built Buzzer sounds
-
NMS compatible NO/NC output is also activated
-
In case of Fire additionally a hooter also sounds. This hooter can be provided inside the panel or provision can be given for an external hooter.
|
 |
Bypass facility for every zone – Intrusion, Temperature and Fire. |
 |
Rugged industrial design, suitable for rough usage |
Details are as follows:
| Fire Detection |
 |
Fire detection is done using Smoke Sensors (One Ionisation or one Optical) that are interfaced with the Central Panel. (Apollo or System Sensor) |
 |
The Smoke detector comes with blinking LED to indicate the status of the sensor |
 |
The central panel has the bypass controls. |
 |
The Smoke sensors draws it’s power from central panel |
 |
In case of fire, the Fire LED lights up on the central panel and Buzzer starts sounding. Also, the NMS is activated. In case of Fire additionally a hooter also sounds. This hooter can be provided inside the panel or provision can be given for an external hooter. User needs to specify this at the time of placement of order. |
 |
Once the Fire condition is removed, the LED, Buzzer, Hooter and NMS are reset. |
 |
Fire Bypass switch can be used to Bypass this zone. |
| Temperature Alarm/Sensor features |
 |
Continuous monitoring of temperature on 24 x 7 x 365 basis |
 |
User defined temperature cut-off at which alarm goes off. The cut-off temperature can be modified by rotating a dial and not by cumbersome jumper setting |
 |
Temperature Bypass switch can be used to Bypass this zone. |
Intrusion detection
Intrusion is detected using a magnetic switch that has to be mounted on the door of the enclosure.
 |
When the door is opened, the Door LED lights up on the central panel and Buzzer starts sounding. Also, the NMS is activated. |
 |
When the door is closed these conditions are removed |
 |
Door Bypass switch can be used to Bypass this zone. |
Note : We can customize the features if desired. We have advanced models with delay zones for buzzer, NMS etc.
|